(0020,0052)
Frame of Reference UID
Keyword: FrameOfReferenceUID
Uniquely identifies the frame of reference for the image. Shared across series acquired in the same patient coordinate system.
Tag Attributes
- Tag ID
- (0020,0052)
- Compact
- 00200052
- Keyword
- FrameOfReferenceUID
- VR
- UI — Unique Identifier (UID)
- VM
- 1
- Required
- Type 1 — required, with a value
- PS3.15
- Basic Profile action U
- Retired
- No
Defined in
What Frame of Reference UID contains
Frame of Reference UID names the patient-based coordinate system in which Image Position (Patient) and Image Orientation (Patient) are expressed. Images that share it can be overlaid directly; images with different values need a registration before their positions mean the same thing.
Series acquired while the patient stays in place share one Frame of Reference, for example the CT and PET of a PET/CT scan or several MR sequences in one session. When the patient is repositioned, a new Frame of Reference is needed.
It is Type 1 in the Frame of Reference Module, and PS3.15 de-identification replaces it consistently across the whole data set (action U), so related series still share a value afterwards.
All series acquired in a single gantry setup should share the same Frame of Reference UID. Enables spatial co-registration between series (e.g., CT + PET fusion).
Group 0020 holds the identifiers and numbers that tie instances into series and studies, and the geometry of the patient coordinate system.
Value format: UI (Unique Identifier (UID)), VM 1
(0020,0052) FrameOfReferenceUID has Value Representation UI (Unique Identifier (UID)) and Value Multiplicity 1, which means exactly one value.
UI — Unique Identifier (UID)
A globally unique identifier made of numeric components separated by periods, for example 1.2.840.10008.1.2.1. An odd-length value is padded with one trailing NULL byte.
- Length
- 64 bytes maximum
- Characters
- The digits 0–9 and the period.
Example value
2.25.268434151379112284556391137408731940317
Format mistakes to avoid
- A component may not start with a zero unless it is the single digit 0, so 1.2.03 is invalid.
- Letters, spaces and values longer than 64 bytes are invalid.
Where FrameOfReferenceUID appears
| Defined in | Type | Meaning |
|---|---|---|
| Frame of Reference ModulePS3.3 C.7.4.1 | 1 | Required, and it must have a value. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
PS3.15 Table E.1-1 gives Frame of Reference UID the Basic Profile action U: replace it with a new UID that stays consistent across every instance in the de-identified set.
With the Retain UIDs Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
Series-level attributes group and order images in viewers. Copy them unchanged in a migration, and compare series counts and series descriptions between the old and the new archive when checking that a study arrived complete.
Common errors and how to fix them
A viewer will not fuse two series that look aligned
They carry different Frame of Reference UIDs, so the viewer cannot assume a shared coordinate system. Register them, or check whether a processing step replaced the UID on one series.
Two series fuse but are misaligned
They share a Frame of Reference UID although the patient moved between them. The device should have started a new frame of reference; register the series manually.
Troubleshooting: PET/CT or CT/MR fusion failures in the viewer are often caused by different Frame of Reference UIDs when they should match. Verify on multimodality scanners.
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Frame of Reference UID: frequently asked questions
What is DICOM tag (0020,0052) Frame of Reference UID?
Uniquely identifies the frame of reference for the image. Shared across series acquired in the same patient coordinate system. Frame of Reference UID names the patient-based coordinate system in which Image Position (Patient) and Image Orientation (Patient) are expressed. Images that share it can be overlaid directly; images with different values need a registration before their positions mean the same thing.
What VR and VM does Frame of Reference UID (0020,0052) have?
(0020,0052) FrameOfReferenceUID has Value Representation UI (Unique Identifier (UID)) and Value Multiplicity 1, which means exactly one value. A globally unique identifier made of numeric components separated by periods, for example 1.2.840.10008.1.2.1. An odd-length value is padded with one trailing NULL byte. Maximum length: 64 bytes maximum.
Is Frame of Reference UID (0020,0052) required?
In the Frame of Reference Module (PS3.3 C.7.4.1) it is Type 1: required, and it must have a value.
How is Frame of Reference UID handled when de-identifying DICOM files?
PS3.15 Table E.1-1 gives Frame of Reference UID the Basic Profile action U: replace it with a new UID that stays consistent across every instance in the de-identified set. With the Retain UIDs Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).
How do I troubleshoot Frame of Reference UID (0020,0052)?
PET/CT or CT/MR fusion failures in the viewer are often caused by different Frame of Reference UIDs when they should match. Verify on multimodality scanners.
Check FrameOfReferenceUID in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: