(0008,1070)
Operators' Name
Keyword: OperatorsName
Name(s) of the operator(s) supporting the Series.
Tag Attributes
- Tag ID
- (0008,1070)
- Compact
- 00081070
- Keyword
- OperatorsName
- VR
- PN — Person Name
- VM
- 1-n
- Required
- Type 3 — optional
- PS3.15
- Basic Profile action X/Z/D
- Retired
- No
Defined in
What Operators' Name contains
Usually the radiographers or technologists who performed the series. Several names are separated by backslashes.
Group 0008 holds general identifying information: what kind of object this is, when it was made, and by which equipment and people.
Value format: PN (Person Name), VM 1-n
(0008,1070) OperatorsName has Value Representation PN (Person Name) and Value Multiplicity 1-n, which means one or more values, separated by a backslash (\).
PN — Person Name
A name in five components separated by carets: family name, given name, middle name, prefix and suffix, for example DOE^JANE. Up to three component groups (alphabetic, ideographic and phonetic) can follow each other, separated by an equals sign.
- Length
- 64 characters maximum per component group
- Characters
- The default character repertoire, or the one set by Specific Character Set (0008,0005). The backslash is not allowed.
Example value
TAYLOR^SAM\LEE^KIM
Format mistakes to avoid
- Doe, Jane is stored as a single family-name component. Write DOE^JANE so systems can find the given name.
- Trailing empty components may be left out, so DOE^JANE and DOE^JANE^^^ are the same name and should match.
Where OperatorsName appears
| Defined in | Type | Meaning |
|---|---|---|
| General Series ModulePS3.3 C.7.3.1 | 3 | Optional. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
PS3.15 Table E.1-1 gives Operators' Name the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1).
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
Series-level attributes group and order images in viewers. Copy them unchanged in a migration, and compare series counts and series descriptions between the old and the new archive when checking that a study arrived complete.
Common errors and how to fix them
Troubleshooting: Configure modality to capture technologist login and populate this tag automatically. Manual free-text entry leads to inconsistent data.
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Operators' Name: frequently asked questions
What is DICOM tag (0008,1070) Operators' Name?
Name(s) of the operator(s) supporting the Series.
What VR and VM does Operators' Name (0008,1070) have?
(0008,1070) OperatorsName has Value Representation PN (Person Name) and Value Multiplicity 1-n, which means one or more values, separated by a backslash (\). A name in five components separated by carets: family name, given name, middle name, prefix and suffix, for example DOE^JANE. Up to three component groups (alphabetic, ideographic and phonetic) can follow each other, separated by an equals sign. Maximum length: 64 characters maximum per component group.
Is Operators' Name (0008,1070) required?
In the General Series Module (PS3.3 C.7.3.1) it is Type 3: optional.
How is Operators' Name handled when de-identifying DICOM files?
PS3.15 Table E.1-1 gives Operators' Name the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1).
How do I troubleshoot Operators' Name (0008,1070)?
Configure modality to capture technologist login and populate this tag automatically. Manual free-text entry leads to inconsistent data.
Check OperatorsName in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: