(0008,0064)
Conversion Type
Keyword: ConversionType
Describes how a Secondary Capture image was produced, for example from digitized film, a video signal or a workstation screen.
Tag Attributes
- Tag ID
- (0008,0064)
- Compact
- 00080064
- Keyword
- ConversionType
- VR
- CS — Code String
- VM
- 1
- Required
- Type 1 — required, with a value
- PS3.15
- Not listed in PS3.15 Table E.1-1
- Retired
- No
Defined in
What Conversion Type contains
Every Secondary Capture image must carry it. It records the origin of the image, which matters when judging whether a converted image is fit for diagnosis.
Group 0008 holds general identifying information: what kind of object this is, when it was made, and by which equipment and people.
Value format: CS (Code String), VM 1
(0008,0064) ConversionType has Value Representation CS (Code String) and Value Multiplicity 1, which means exactly one value.
CS — Code String
A short code. Leading and trailing spaces are not significant. Codes are usually Defined Terms or Enumerated Values listed by the standard.
- Length
- 16 bytes maximum
- Characters
- Uppercase letters A–Z, digits 0–9, the space and the underscore.
Example value
WSD
Format mistakes to avoid
- Lowercase letters, hyphens and other punctuation are not allowed, so ct or Head-Neck are invalid code strings.
- Values longer than 16 characters are invalid.
Common values
| Value | Meaning |
|---|---|
| DV | Digitized Video |
| DI | Digital Interface |
| DF | Digitized Film |
| WSD | Workstation |
| SD | Scanned Document |
| SI | Scanned Image |
| DRW | Drawing |
| SYN | Synthetic Image |
Where ConversionType appears
| Defined in | Type | Meaning |
|---|---|---|
| SC Equipment ModulePS3.3 C.8.6.1 | 1 | Required, and it must have a value. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
Conversion Type is not listed in PS3.15 Table E.1-1, so the Basic Application Level Confidentiality Profile gives no specific action for it.
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
When studies move between archives, the objects should arrive with this attribute exactly as it was sent. Compare a sample of objects on both sides after the transfer rather than assuming nothing changed.
Common errors and how to fix them
Troubleshooting: A Secondary Capture object without Conversion Type is not valid. Set it in the software that creates the screen captures or scans.
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Conversion Type: frequently asked questions
What is DICOM tag (0008,0064) Conversion Type?
Describes how a Secondary Capture image was produced, for example from digitized film, a video signal or a workstation screen.
What VR and VM does Conversion Type (0008,0064) have?
(0008,0064) ConversionType has Value Representation CS (Code String) and Value Multiplicity 1, which means exactly one value. A short code. Leading and trailing spaces are not significant. Codes are usually Defined Terms or Enumerated Values listed by the standard. Maximum length: 16 bytes maximum.
Is Conversion Type (0008,0064) required?
In the SC Equipment Module (PS3.3 C.8.6.1) it is Type 1: required, and it must have a value.
How is Conversion Type handled when de-identifying DICOM files?
Conversion Type is not listed in PS3.15 Table E.1-1, so the Basic Application Level Confidentiality Profile gives no specific action for it.
How do I troubleshoot Conversion Type (0008,0064)?
A Secondary Capture object without Conversion Type is not valid. Set it in the software that creates the screen captures or scans.
Check ConversionType in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: