(0008,0032)
Acquisition Time
Keyword: AcquisitionTime
The time the acquisition of data that resulted in this image started.
Tag Attributes
- Tag ID
- (0008,0032)
- Compact
- 00080032
- Keyword
- AcquisitionTime
- VR
- TM — Time
- VM
- 1
- Required
- Type 3 — optional
- PS3.15
- Basic Profile action X/Z
- Retired
- No
Defined in
What Acquisition Time contains
Used for temporal alignment in dynamic studies, cardiac gating, and breath-hold timing analysis.
Group 0008 holds general identifying information: what kind of object this is, when it was made, and by which equipment and people.
Value format: TM (Time), VM 1
(0008,0032) AcquisitionTime has Value Representation TM (Time) and Value Multiplicity 1, which means exactly one value.
TM — Time
A time of day on a 24-hour clock in the format HHMMSS.FFFFFF. Components on the right may be left out, so 14, 1425 and 142530.5 are all valid.
- Length
- 14 bytes maximum
- Characters
- The digits 0–9 and the period.
Example value
143015.250
Format mistakes to avoid
- Colons (14:25:30) come from the old ACR-NEMA format and are not valid in DICOM.
- A time carries no time zone. If one is needed, Timezone Offset From UTC (0008,0201) holds it.
Where AcquisitionTime appears
| Defined in | Type | Meaning |
|---|---|---|
| General Acquisition ModulePS3.3 C.7.10.1 | 3 | Optional. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
PS3.15 Table E.1-1 gives Acquisition Time the Basic Profile action X/Z: remove it; if the IOD requires the attribute to be present, keep it with an empty or dummy value instead.
With the Retain Longitudinal Temporal Information with Full Dates Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).
With the Retain Longitudinal Temporal Information with Modified Dates Option, the action is C: clean it: replace values with similar values that carry no identifying information.
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
Acquisition parameters describe what happened at the scanner and should never change after the fact. A migration copies them as they are; a difference between the source and the copy points to a fault in the transfer, not to a correction.
Common errors and how to fix them
Troubleshooting: In dynamic contrast-enhanced studies, missing Acquisition Time prevents phase identification (pre-contrast, arterial, portal, delayed).
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Acquisition Time: frequently asked questions
What is DICOM tag (0008,0032) Acquisition Time?
The time the acquisition of data that resulted in this image started.
What VR and VM does Acquisition Time (0008,0032) have?
(0008,0032) AcquisitionTime has Value Representation TM (Time) and Value Multiplicity 1, which means exactly one value. A time of day on a 24-hour clock in the format HHMMSS.FFFFFF. Components on the right may be left out, so 14, 1425 and 142530.5 are all valid. Maximum length: 14 bytes maximum.
Is Acquisition Time (0008,0032) required?
In the General Acquisition Module (PS3.3 C.7.10.1) it is Type 3: optional.
How is Acquisition Time handled when de-identifying DICOM files?
PS3.15 Table E.1-1 gives Acquisition Time the Basic Profile action X/Z: remove it; if the IOD requires the attribute to be present, keep it with an empty or dummy value instead. With the Retain Longitudinal Temporal Information with Full Dates Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item). With the Retain Longitudinal Temporal Information with Modified Dates Option, the action is C: clean it: replace values with similar values that carry no identifying information.
How do I troubleshoot Acquisition Time (0008,0032)?
In dynamic contrast-enhanced studies, missing Acquisition Time prevents phase identification (pre-contrast, arterial, portal, delayed).
Check AcquisitionTime in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: