(0018,0010)
Contrast/Bolus Agent
Keyword: ContrastBolusAgent
Contrast or bolus agent administered to the patient during this acquisition.
Tag Attributes
- Tag ID
- (0018,0010)
- Compact
- 00180010
- Keyword
- ContrastBolusAgent
- VR
- LO — Long String
- VM
- 1
- Required
- Type 2 — required, may be empty
- PS3.15
- Basic Profile action Z/D
- Retired
- No
Defined in
What Contrast/Bolus Agent contains
Free text naming the contrast or bolus agent. The same module also offers a coded Contrast/Bolus Agent Sequence (Type 3), which is easier for software to read.
Group 0018 holds acquisition information: how the data were acquired and with which settings.
Value format: LO (Long String), VM 1
(0018,0010) ContrastBolusAgent has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value.
LO — Long String
A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values.
- Length
- 64 characters maximum
- Characters
- The default character repertoire, or the one set by Specific Character Set (0008,0005).
Example value
IOHEXOL
Format mistakes to avoid
- A backslash inside the text splits it into two values.
- Accented or non-Latin characters need a matching Specific Character Set (0008,0005), or receivers decode them wrongly.
Where ContrastBolusAgent appears
| Defined in | Type | Meaning |
|---|---|---|
| Contrast/Bolus ModulePS3.3 C.7.6.4 | 2 | Required, but it may be empty (zero length) when the value is unknown. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
PS3.15 Table E.1-1 gives Contrast/Bolus Agent the Basic Profile action Z/D: replace it with an empty value; if the IOD requires it to have a value, use a dummy value instead.
With the Clean Descriptors Option, the action is C: clean it: replace values with similar values that carry no identifying information.
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
Acquisition parameters describe what happened at the scanner and should never change after the fact. A migration copies them as they are; a difference between the source and the copy points to a fault in the transfer, not to a correction.
Common errors and how to fix them
Troubleshooting: Because it is free text, the same agent is spelled in many ways. Post-processing that picks contrast-enhanced series should not depend on an exact string; use the coded sequence where the device provides it.
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Contrast/Bolus Agent: frequently asked questions
What is DICOM tag (0018,0010) Contrast/Bolus Agent?
Contrast or bolus agent administered to the patient during this acquisition.
What VR and VM does Contrast/Bolus Agent (0018,0010) have?
(0018,0010) ContrastBolusAgent has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value. A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values. Maximum length: 64 characters maximum.
Is Contrast/Bolus Agent (0018,0010) required?
In the Contrast/Bolus Module (PS3.3 C.7.6.4) it is Type 2: required, but it may be empty (zero length) when the value is unknown.
How is Contrast/Bolus Agent handled when de-identifying DICOM files?
PS3.15 Table E.1-1 gives Contrast/Bolus Agent the Basic Profile action Z/D: replace it with an empty value; if the IOD requires it to have a value, use a dummy value instead. With the Clean Descriptors Option, the action is C: clean it: replace values with similar values that carry no identifying information.
How do I troubleshoot Contrast/Bolus Agent (0018,0010)?
Because it is free text, the same agent is spelled in many ways. Post-processing that picks contrast-enhanced series should not depend on an exact string; use the coded sequence where the device provides it.
Check ContrastBolusAgent in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: