MajwareMAJWARE
ERR-3 = 200RejectTable 0357

HL7 200 — Unsupported message type

Code 200 means the message type in MSH-9 (e.g. ADT, ORU, SIU) is not supported by the receiving application or interface at all.

When you see 200 (Error Condition Code)

Raised when the receiver has no handler or channel for the message type being sent. Usually paired with an AR acknowledgment.

Common causes

  • Sending a message type the receiver was never configured to accept (e.g. SIU to an ADT-only feed).
  • A typo or wrong value in the MSH-9 message code.
  • Routing the message to the wrong channel/endpoint on the receiver.

How to fix it

  1. 1Confirm MSH-9 contains the correct message type and that the receiver supports it.
  2. 2Verify the message is routed to a channel configured for that type; an interface engine may reject it before the application.
  3. 3If the type is genuinely needed, work with the receiving vendor to enable support or add a channel.

Example ACK message

A representative acknowledgment carrying ERR-3 = 200. Open it in the HL7 Viewer to inspect every field.

HL7 v2.x Message
1MSH||^~\&|RECEIVER|HOSP|SENDER|HOSP|20260310143440||ACK^A01^ACK|ACK00020|P|2.5.1
2MSA||AR|MSG00001|Unsupported message type
3ERR||||200^Unsupported message type^HL70357|E|||MSH.9 message type 'SIU' not supported on this interface

Related codes

Frequently asked questions

What does HL7 error code 200 mean?

Code 200 (Unsupported message type) means the receiver does not support the message type in MSH-9. Confirm MSH-9 is correct and routed to the right channel, or have the receiver enable support for that type.

Debug your ACK in the viewer

Paste the ACK (or original message) and get instant segment parsing, MSA/ERR decoding, and validation. Free, client-side, no signup.

Open HL7 Message Viewer →

All HL7 error & ACK codes

Browse every acknowledgment code (Table 0008) and error condition code (Table 0357) with causes, fixes, and examples.

HL7 Error Code Reference →