(0018,1000)
Device Serial Number
Keyword: DeviceSerialNumber
Manufacturer's serial number of the equipment that produced the composite instances.
Tag Attributes
- Tag ID
- (0018,1000)
- Compact
- 00181000
- Keyword
- DeviceSerialNumber
- VR
- LO — Long String
- VM
- 1
- Required
- Type 3 — optional
- PS3.15
- Basic Profile action X/Z/D
- Retired
- No
Defined in
What Device Serial Number contains
Used for equipment tracking, preventive maintenance scheduling, and incident investigation. Essential for multi-unit sites.
Group 0018 holds acquisition information: how the data were acquired and with which settings.
Value format: LO (Long String), VM 1
(0018,1000) DeviceSerialNumber has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value.
LO — Long String
A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values.
- Length
- 64 characters maximum
- Characters
- The default character repertoire, or the one set by Specific Character Set (0008,0005).
Example value
SN-104233
Format mistakes to avoid
- A backslash inside the text splits it into two values.
- Accented or non-Latin characters need a matching Specific Character Set (0008,0005), or receivers decode them wrongly.
Where DeviceSerialNumber appears
| Defined in | Type | Meaning |
|---|---|---|
| General Equipment ModulePS3.3 C.7.5.1 | 3 | Optional. |
A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.
De-identification (PS3.15)
PS3.15 Table E.1-1 gives Device Serial Number the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1).
With the Retain Device Identity Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).
To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.
In archives and migrations
Equipment attributes identify the device that created the images. A migration keeps them as they are, which also keeps the record of which scanner produced which study.
Common errors and how to fix them
Troubleshooting: When a specific modality produces encoding errors, use serial number to identify the exact unit for service dispatch.
Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.
Device Serial Number: frequently asked questions
What is DICOM tag (0018,1000) Device Serial Number?
Manufacturer's serial number of the equipment that produced the composite instances.
What VR and VM does Device Serial Number (0018,1000) have?
(0018,1000) DeviceSerialNumber has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value. A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values. Maximum length: 64 characters maximum.
Is Device Serial Number (0018,1000) required?
In the General Equipment Module (PS3.3 C.7.5.1) it is Type 3: optional.
How is Device Serial Number handled when de-identifying DICOM files?
PS3.15 Table E.1-1 gives Device Serial Number the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1). With the Retain Device Identity Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).
How do I troubleshoot Device Serial Number (0018,1000)?
When a specific modality produces encoding errors, use serial number to identify the exact unit for service dispatch.
Check DeviceSerialNumber in your files
The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.
Open DICOM Validator →Remove patient data before sharing
The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.
Open DICOM Anonymizer →Sources
Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: