MajwareMAJWARE
Equipment

(0018,1000)

Device Serial Number

Keyword: DeviceSerialNumber

Manufacturer's serial number of the equipment that produced the composite instances.

Tag Attributes

Tag ID
(0018,1000)
Compact
00181000
Keyword
DeviceSerialNumber
VR
LO — Long String
VM
1
Required
Type 3 — optional
PS3.15
Basic Profile action X/Z/D
Retired
No

Defined in

General Equipment Module

What Device Serial Number contains

Used for equipment tracking, preventive maintenance scheduling, and incident investigation. Essential for multi-unit sites.

Group 0018 holds acquisition information: how the data were acquired and with which settings.

Value format: LO (Long String), VM 1

(0018,1000) DeviceSerialNumber has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value.

LO — Long String

A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values.

Length
64 characters maximum
Characters
The default character repertoire, or the one set by Specific Character Set (0008,0005).

Example value

SN-104233

Format mistakes to avoid

  • A backslash inside the text splits it into two values.
  • Accented or non-Latin characters need a matching Specific Character Set (0008,0005), or receivers decode them wrongly.

Where DeviceSerialNumber appears

Defined inTypeMeaning
General Equipment ModulePS3.3 C.7.5.13Optional.

A module lists the attributes an object must or may carry. Many IODs (CT Image, MR Image, Secondary Capture and others) include the same module, and an IOD-specific module can make an attribute stricter than the general one.

De-identification (PS3.15)

PS3.15 Table E.1-1 gives Device Serial Number the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1).

With the Retain Device Identity Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).

To see how de-identification changes your own files, try the free DICOM Anonymizer, which runs in the browser and uploads nothing.

In archives and migrations

Equipment attributes identify the device that created the images. A migration keeps them as they are, which also keeps the record of which scanner produced which study.

Common errors and how to fix them

Troubleshooting: When a specific modality produces encoding errors, use serial number to identify the exact unit for service dispatch.

Check a file in seconds with the free DICOM Validator: it reads the header in your browser, lists the tags with their values, and flags missing or malformed key attributes.

Device Serial Number: frequently asked questions

What is DICOM tag (0018,1000) Device Serial Number?

Manufacturer's serial number of the equipment that produced the composite instances.

What VR and VM does Device Serial Number (0018,1000) have?

(0018,1000) DeviceSerialNumber has Value Representation LO (Long String) and Value Multiplicity 1, which means exactly one value. A character string that may be padded with leading or trailing spaces. The backslash is not allowed, because it separates values. Maximum length: 64 characters maximum.

Is Device Serial Number (0018,1000) required?

In the General Equipment Module (PS3.3 C.7.5.1) it is Type 3: optional.

How is Device Serial Number handled when de-identifying DICOM files?

PS3.15 Table E.1-1 gives Device Serial Number the Basic Profile action X/Z/D: remove it; if the IOD requires the attribute, leave it empty where it may be empty (Type 2) or give it a dummy value where it must have one (Type 1). With the Retain Device Identity Option, the action is K: keep it unchanged (a sequence is kept but cleaned item by item).

How do I troubleshoot Device Serial Number (0018,1000)?

When a specific modality produces encoding errors, use serial number to identify the exact unit for service dispatch.

Check DeviceSerialNumber in your files

The free DICOM Validator lists every header tag and flags problems. Files stay in your browser.

Open DICOM Validator →

Remove patient data before sharing

The free DICOM Anonymizer applies a de-identification profile in your browser, with no upload.

Open DICOM Anonymizer →

Sources

Checked against the DICOM standard, release 2026d. Module Types, query keys and de-identification actions come from these tables: